19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable
HomeHome > Products > Cables > 19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable
19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable

19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable

19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable Application: XLPE Insulated power cable is used
Basic Info
Model NO. YJLSV72
Wire Core Material Aluminium Wire
Certification ISO, CCC, CE, RoHS, VDE, SABS
Model Yjlsv72
Brand Henan Jiapu
Voltage Rating up to 35kv
No.of Cores 1-5 Cores
Max Working Temp 90 Degrees
Standards IEC60502-2 VDE 0276-620 AS/NZS1429.1 Icea S93-639
Capacity 2000km/Month
Delivery Length Accord with The Request
Transport Package Wooden Drum or Wooden&Steel Drum
Specification IEC, ASTM, DIN, BS, GB, Any standard
Trademark Jiapu
Origin Henan China
HS Code 8544601400
Production Capacity 2000km/Month
Product Description
19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable
Application: XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.Prpperty:1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.4.Excellent electrical performance, resistance to chemical corrosion.5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.Specification:IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

2.5

0.1

1.2

0.2

1.9

37.9

1.87

2.32

3 X 35

6.9

2.5

0.1

1.3

0.5

2.0

41.5

2.10

2.73

3 X50

8.2

2.5

0.1

1.3

0.5

2.0

44.3

2.37

3.22

3 X 70

9.7

2.5

0.1

1.4

0.5

2.1

47.9

2.77

4.00

3 X 95

11.3

2.5

0.1

1.4

0.5

2.2

51.6

3.21

4.91

3 X 120

12.8

2.5

0.1

1.5

0.5

2.4

55.4

3.69

5.84

3 X 150

14.2

2.5

0.1

1.5

0.5

2.5

58.6

4.15

6.85

3 X 185

15.9

2.5

0.1

1.5

0.5

2.6

62.5

4.73

8.11

3 X 240

18.3

2.6

0.1

1.6

0.5

2.7

68.5

5.62

10.05

3 X 300

20.4

2.8

0.1

1.7

0.5

2.9

74.5

6.55

12.11

3 X 400

23.2

3.0

0.1

1.9

0.8

3.2

83.6

8.78

15.86

3 X 500

26.4

3.2

0.1

2.1

0.8

3.4

93.0

10.52

18.85

2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

3.4

0.1

1.3

0.5

2.0

43.4

2.16

2.61

3 X 35

6.9

3.4

0.1

1.3

0.5

2.0

45.4

2.36

2.99

3 X50

8.2

3.4

0.1

1.4

0.5

2.2

48.8

2.69

3.54

3 X 70

9.7

3.4

0.1

1.5

0.5

2.3

52.4

3.10

4.33

3 X 95

11.3

3.4

0.1

1.5

0.5

2.4

56.1

3.56

5.26

3 X 120

12.8

3.4

0.1

1.5

0.5

2.5

59.5

4.04

6.19

3 X 150

14.2

3.4

0.1

1.5

0.5

2.6

62.7

4.49

7.19

3 X 185

15.9

3.4

0.1

1.6

0.5

2.6

66.6

5.12

8.49

3 X 240

18.3

3.4

0.1

1.7

0.5

2.8

72.4

5.99

10.42

3 X 300

20.4

3.4

0.1

1.8

0.5

3.0

77.5

6.86

12.42

3 X 400

23.2

3.4

0.1

1.9

0.8

3.2

85.4

8.97

16.05

3 X 500

26.4

3.4

0.1

2.0

0.8

3.4

93.7

10.65

19.50

3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

4.5

0.1

1.4

0.5

2.1

48.6

2.53

2.98

3 X 35

6.9

4.5

0.1

1.4

0.5

2.2

50.7

2.76

3.39

3 X50

8.2

4.5

0.1

1.5

0.5

2.3

53.9

3.10

3.95

3 X 70

9.7

4.5

0.1

1.5

0.5

2.4

57.4

3.51

4.74

3 X 95

11.3

4.5

0.1

1.5

0.5

2.6

61.2

4.05

5.75

3 X 120

12.8

4.5

0.1

1.6

0.5

2.6

64.7

4.56

6.72

3 X 150

14.2

4.5

0.1

1.6

0.5

2.7

67.9

5.04

7.74

3 X 185

15.9

4.5

0.1

1.7

0.5

2.8

71.9

5.66

9.04

3 X 240

18.3

4.5

0.1

1.8

0.5

3.0

77.7

6.56

11.00

3 X 300

20.4

4.5

0.1

1.9

0.8

3.2

84.1

8.39

13.96

3 X 400

23.2

4.5

0.1

2.0

0.8

3.3

90.5

9.71

16.79

3 X 500

26.4

4.5

0.1

2.1

0.8

3.5

98.8

11.45

20.57

4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25










3 X 35

6.9

5.5

0.1

1.5

0.5

2.4

55.6

3.14

3.77

3 X50

8.2

5.5

0.1

1.5

0.5

2.5

58.6

3.49

4.34

3 X 70

9.7

5.5

0.1

1.5

0.5

2.6

62.1

3.93

5.16

3 X 95

11.3

5.5

0.1

1.6

0.5

2.6

65.7

4.46

6.16

3 X 120

12.8

5.5

0.1

1.7

0.5

2.7

69.4

5.00

7.15

3 X 150

14.2

5.5

0.1

1.7

0.5

2.8

72.6

5.49

8.19

3 X 185

15.9

5.5

0.1

1.8

0.5

3.0

76.9

6.16

9.53

3 X 240

18.3

5.5

0.1

1.9

0.8

3.2

83.9

7.87

12.31

3 X 300

20.4

5.5

0.1

2.0

0.8

3.2

88.6

8.96

14.52

3 X 400

23.2

5.5

0.1

2.1

0.8

3.5

95.4

10.35

17.43

3 X 500

26.4

5.5

0.1

2.2

0.8

3.7

103.7

12.45

20.23

5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25










3 X 35










3 X50

8.2

8.0

0.1

1.7

0.5

2.8

70.4

4.56

5.41

3 X 70

9.7

8.0

0.1

1.7

0.5

2.9

73.9

5.04

6.26

3 X 95

11.3

8.0

0.1

1.8

0.5

3.0

77.7

5.62

7.32

3 X 120

12.8

8.0

0.1

1.9

0.8

3.2

82.8

6.99

9.15

3 X 150

14.2

8.0

0.1

1.9

0.8

3.2

85.8

7.56

10.26

3 X 185

15.9

8.0

0.1

2.0

0.8

3.3

89.9

8.30

11.67

3 X 240

18.3

8.0

0.1

2.1

0.8

3.5

95.7

9.36

13.79

3 X 300

20.4

8.0

0.1

2.2

0.8

3.6

100.6

10.51

16.07

3 X 400

23.2

8.0

0.1

2.3

0.8

3.8

107.2

11.99

19.07

3 X 500

26.4

8.0

0.1

2.4

0.8

4.0

120.1

14.15

23.85

19/33kv XLPE Insluated and Steel Wire Armored Electric Cable Power Cable


FAQ1. How many years has Henan Jiapu Cable Group been in production?Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China 2. What kinds of products does Jiapu Cable manufacture?1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;3)PVC Insulated (Flexible ) Wire ;4) PVC Insulated and Sheathed (Armoured) Power Cable;5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on; 3. What kind of certifications do you have?SABS, CE, ISO9001-2000, SGS 4.Which markets do you involve mainly in?Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc. 5. Which standards do you comply with when you produce the electrical wires and cables ?We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply. 6. What is the min.order quantity ?It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request. 7. What is the production capacity per week or per month ?For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables. 8. Do you supply the customers with installation service in foreign country ?We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.